1010 Insitu Cross-Duct-CEMS
[Single-channel Co or Co2 or So2 or NOx]
Model 1010 for CO or C02, 1021 for So2, and 1030 for NOx
1010 Insitu Cross-Duct-CEMS

 

With no sampling system to maintain, 1000 cross-duct monitors are easy to install and simple to operate, vital for a plant where there may be little or no technical support available.

 

The 1000 analyser may be used as a complete stand-alone monitor or as part of an integrated emission monitoring, logging and reporting system. The instrument is particularly suited to large and dirty processes.

 

Low cost single gas analyzer for small, medium and large Boilers.

 

Simple installation with only FOUR modules, Transmitter, Receiver, Power supply and Signal Processor, all NEMA 4X rated.

 

Most suitable for emissions monitoring as well as closed loop online insitu process control with 10 secs response time.

 

Minimal lens contamination

» High-efficiency air purges to maintain optical efficiency

 

Automatic on-line zero calibration

» Continual correction using integral reference gas cell

 

Real-time normalization

» To standard reference conditions

 

Low maintenance overheads

» Only simple, infrequent checks to windows required

 

Choice of data presentation

» Ppm, mg/m3 and mg/Nm3

 

Optional independent verification

» Using certified test cellsor filters

 

One-year parts & labor warranty for complete peace of mind

 

1010 Insitu Cross-Duct-CEMS

 

Summary Specification



Span:
  • Co & NO selectable from 0-100 ppm to 0-10000 ppm, within the range 200 to 6000 ppm.meter at STP
  • So2 Selectable from 0-100 ppm to 0-10000 ppm, within the range 200 to 6000 ppm.meter at STP


  • Display Units: ppm; mg/m3 (measured); mg/Nm3 (normalized)

    Accuracy: + 2% of measurement or + 5ppm whichever is greater

    Outputs: 
    Analog 4~20mA isolated, 500 ohms max
    High Alarm Volt free contact
    Data Valid Volt free contact (both rated @ 10 Amps @ 250 V)

    Inputs: 
    Oxygen 4~20mA; Temp: 4~20mA; Pressure: 4~20mA
    Plant Status contact  Volt free contact
    Serial Port For remote instrument operation, normalizing inputs and outputs

    Path length: 0.5 to 8 meters

    Flue gas temperature: 0 to 300 deg C

    Construction: Cast Aluminum, fully sealed to IP65

    Transmitter: Electrically heated Silicon Nitride Cylinder

    Detector: Lithium Tantalite Pyro-electric detector

    Ambient temperature limits: -20 deg C to 70 deg C

    Power Requirements: 85 to 132/170 to 264 V AC, 50/60 Hz, and 50 VA

    Air purge consumption: 1.0 l/s @ 1 bar (compressed air) 5 l/s (blower air)

    The range of the output span is quoted in ppm.meter.