G-CEM4000 Insitu CEMS Probe

G-CEM4000 Insitu CEMS Probe

 

The G-CEM4000 is a multi-channel analyzer using Non-Dispersive Infrared Absorption (NDIR) technology. It provides high accuracy and low maintenance measurements of CO, CO2, NO, NO2, SO2, HCl, & H2O. Its performance can be verified automatically or manually on demand by injection of zero and span protocol gases into the probe sample chamber.

 

  • Multiple gases in one probe (up to 6 max)
  • No sampling system required
  • Insitu calibration verification
  • Fully compliant to 40CFR60 and 75
  • Remote MODEM/Web access
  • Automatic daily calibrations and quarterly audits
  •  

    Low cost NDIR insitu online continuous monitoring for 6 gases in one probe, two insertion lengths

     

    Simple installation with only TWO modules, insitu probe flange mounted and Signal Processor, both NEMA 4X rated

     

    Most suitable for EPA compliance emissions monitoring as well as closed loop online insitu process control with 10 secs response time

     

    Heated probe available for wet applications



    Summary Specification


    Measurements

    Main measurement channels (1-7): Any combination of up to seven gases from CO/CO2 /NO/NO2 /SO2 /HCl/UHC/H2O
    Measurement Limits (maximum): CO/NO/NO2 /HCl/UHC 3000 vpm; SO2 25000 vpm; CO2 /H2 O 25%
    Measurement Spans: CO/NO/NO2 /SO2 /HCl/UHC selectable up to 9,999vpm; CO2 /H2 O selectable up to 99%

    Note that although very low spans can be configured, this should not be done without consideration of the measurement uncertainty.>

    Measurement Uncertainty

    CO2 0.2%; H2O ?0.2%; other gases 10vpm or ±2% of measurement (whichever is the greater)

    Measurement Temperature (Flue gas)

    0-200? C (up to 400? C with high temperature probe)

    Measurement Units

    Vpm (% for CO2 and H2 O); mg/m3; ?mg/Nm3
    Display

    Via PC running SmartCOM software; real-time measurements; operating parameters; diagnostic information; set-up menus

    Outputs

    Analogue: One for each main measurement channel (located in SCU) (channels 1 to 7) 0/4-20mA isolated 500 max. Load; fully configurable in measurement units (vpm or %, mg/m3; mg/Nm3), and span
    Logic: (Located in SCU)

    Inputs

    Analogue: Three 4-20mA inputs for normalizing measurements; ±200V DC common mode voltage range (three of these inputs incorporate isolated 24V DC supplies to power loop-powered 2 or 3-wire transducers)
    Serial Port: For connection to bi-directional 4-wire data bus (located in Station terminating at the CDC when installed as part Control unit) of an integrated emission monitoring (IEM) system
    Ambient Temperature: All units are designed to operate in ambient temperatures of -20?C to +50C; Extreme climatic conditions may require further protection
    Enclosures: All units are sealed to IP65 (NEMA 4) standards and are suitable for outdoor installation
    Power Requirements: Power Supply Unit-85-264V AC- 47-62Hz - 200VA
    Purge Gas Requirements: Compressed air/N2 Clean and dry to –20 C; Normal operation 5 l/min; Calibration (10 minutes) 10 l/min

    Dimensions

    Transceiver and probe
    Overall length 2450mm
    Widest diameter 350mm
    Probe length 2150mm
    Transceiver length 300mm
    Transceiver diameter 350mm
    Probe weight 68kg
    Transceiver weight 28kg

    Gas Control Unit
    Height 800mm
    Width 1000mm
    Depth 200mm
    Weight 100kg

    CDC
    Height 300mm
    Width 250mm
    Depth 315mm
    Weight 26kg

    Junction Box
    Height 160mm
    Width 160mm
    Depth 90mm
    Weight 2kg